APPLICABLE
PARAGRAPH OF
SPECIFICATION
Phase C -
Phase B -
Phase A -
Test Stand
Acceleration
At Following Conditions
Rotor Polar
Acceleration
Drive
Drive
Drive
Moment of
Drive
Sec
(Min) Sec
RPM
Sec
6500
12
120
10
2475
2475
8
72
NOTE :
The above values do not allow for flywheel windage
losses, test stand drag, or inertia of the starter.
In order to determine compliance with this specifi-
cation, the test equipment must be calibrated and
specific test results corrected accordingly. If the
acceleration specified for Phase C is not developed
because of test stand drag torque, the test stand
inertia load may be reduced or external power may
be applied to assist acceleration to cutout speed.
Time from end of Phase C to starter cutout shall not
exceed 15 seconds.
Rated Torque Calibration:
4.5.8
Minimum Output Drive Speed (RPM): 6100
Airflow, Max (Lb per Min): 110
Overrunning: The starter output drive shall be
3.3.5
driven for 10 cycles in a clockwise direction
4.5.9
(viewed from the anti-output shaft end) in
accordance with the following 100-hour cycle:
Position of Starter Anti-Drive
Output Shaft
Duration of
End With Respect to Starter
Speed RPM
Running Hours
Horizontal Centerline
14,230
.
14,230
14,230
(Hoarizontal)
50
10,510
2